Coburger Lehrmittelanstalt
Media for Health Education
CLA MEDICAL TRAINING PHANTOMS
CLA Nursing Dolls
CLA Child Nursing Doll
CLA Nursing Care Baby
CLA Arthroscopy
CLA Bronchoscopy
CLA Gastro-Bulboscopy
CLA Intubation
CLA Catheterism
CLA Pelviscopy
CLA Urology
CLA Maintainance Set
CLA EDUCATION MEDIA
CLA SPARE PARTS
ANATOMICAL SOMSO MODELS
|
›
CLA MEDICAL TRAINING PHANTOMS
›
CLA Child Nursing Doll
|
|
Order-No.: CLA 23
Child nursing doll natural size.
Price
on request
|
The doll with a length of 90 cm and weighing 6 kg corresponds to a small child approximately 3 years old. This realistic training doll offers the facility for numerous nursing procedures for training paediatric nurses. This doll made of plastic incorporates durable, new style joint mechanisms which permit most natural movements. As a result training and nursing procedures can be carried out in most practical situations. This small child phantom is available as both a female and male model because of the interchangeable breast and abdominal wall. The abdominal walls incorporate application points for s.c. injections and treatment of wounds (female abdominal wall - OP wound after appendectomy, male abdominal wall - wound treatment after hernia). Upper arms and upper thighs are provided with injection pads. The right arm can be exchanged for an i.v. injection arm. The abdominal walls are equipped with -anus praeter -openings for PEG and suprapubic bladder puncture. The CLA child nursing doll offers the following possibilities for training and instruction: General Nursing procedures a) dressing and undressing b) daily body care c) movement, putting to bed and positioning d) mouth and teeth care e) eye, nose and throat care (including administration of drops) Specific nursing measures under medical supervision for training and demonstration I. Enema a) Lavage enema / clyster b) Intestine tube insertion II. Catheterising and feeding a) Demonstration of catherisation and permanent catheter insertion in female and male genitalia b) Stomach tube insertion through nose and mouth c) Nutrition through bolus administration or by nutrition pump III. Injections and infusions a) I.M. injection (thigh, upper arm) b) S.C. injection (stomach) c) Demonstration of I.V. injection and infusion d) Connection of infusion equipment e) I.V. puncture IV. Lavage a) gastric lavage V. Wound treatment, catheter care and other measures a) Wound care and suture removal b) PEG care c) Anus-praeter care d) Suprapubic bladder puncture with material removal and care in the case of suprapubic bladder drainage e) Tracheostomy care Every child nursing doll is provided with a serial number. This is to be found on the inside in the centre of the chest. It is essential to quote this number in full when reordering. All parts are available individually or as spare parts.
| similar products |
|
Price |
|
| - no picture -
| CLA 23100 Head with painted-on hair and glas eyes |
on request |
|
| - no picture -
| CLA 23114 One pair of glas eyes |
on request |
|
| - no picture -
| CLA 23119/1 Plug for Bronchial Branches |
on request |
|
| - no picture -
| CLA 23130 Plug for Tracheotomy |
on request |
|
| - no picture -
| CLA 23140 Knurled Screw for mounting the head |
on request |
|
| - no picture -
| CLA 23200 Lower section of the body made of rigid plastic |
on request |
|
| - no picture -
| CLA 23205 "Pelvic attachment“ for keeping the bladder |
on request |
|
| - no picture -
| CLA 23206 Chest attachment for holding the abdominal wall |
on request |
|
| - no picture -
| CLA 23207 Female Abdominal Wall, with urethra, but without bladder |
on request |
|
| - no picture -
| CLA 23207/1 Wound pad with suture and drainage for the female abdominal wall |
on request |
|
| - no picture -
| CLA 23207/2 Wound pad with button suture for the female abdominal wall |
on request |
|
| - no picture -
| CLA 23207/3 Wound pad with wound suture for the female abdominal wall |
on request |
|
| - no picture -
| CLA 23207/4 Plug for suprapubic opening on the female Abdominal Wall |
on request |
|
| - no picture -
| CLA 23208 Male Abdominal Wall, with urethra, but without bladder |
on request |
|
| - no picture -
| CLA 23208/1 Injection Pad for the Male Abdominal Wall |
on request |
|
| - no picture -
| CLA 23210 Lungs (1 pair) |
on request |
|
| - no picture -
| CLA 23212 Right lung |
on request |
|
| - no picture -
| CLA 23213 Left lung |
on request |
|
| - no picture -
| CLA 23221 Stomach |
on request |
|
| - no picture -
| CLA 23221/1 Plug-in, Oesophagus/stomach, with small valve opening |
on request |
|
| - no picture -
| CLA 23221/2 Plug-in, Oesophagus/stomach, with large valve opening |
on request |
|
| - no picture -
| CLA 23221/3 Plug |
on request |
|
| - no picture -
| CLA 23300 Upper arm, right |
on request |
|
| - no picture -
| CLA 23301/1 Lower arm, right |
on request |
|
| - no picture -
| CLA 23301/2 Hand, right |
on request |
|
| - no picture -
| CLA 23303 Upper arm left without injection pad |
on request |
|
| - no picture -
| CLA 23304/1 lower arm, left |
on request |
|
| - no picture -
| CLA 23304/2 Hand, left |
on request |
|
| - no picture -
| CLA 23306 Tab red, fastening for the upper arm and the upper leg |
on request |
|
| - no picture -
| CLA 23308 Plug-in thread for the elbow, complete with push-botton, 1 pair |
on request |
|
| - no picture -
| CLA 23312 Injection pad for upper arm left, or injection arm, right |
on request |
|
| - no picture -
| CLA 23330 Injection arm |
on request |
|
| - no picture -
| CLA 23331 Injection pad on the back of the hand for the injection arm |
on request |
|
| - no picture -
| CLA 23332 Injection pad on the side of the hand for the injection arm |
on request |
|
| - no picture -
| CLA 23333 Covers for the elbow of the injection arm |
on request |
|
| - no picture -
| CLA 23334 Bottle for the blood-coloured liquid of the injection arm |
on request |
|
| - no picture -
| CLA 23335 Vein tube for changing 0,5 m |
on request |
|
| - no picture -
| CLA 23336 Y-piece for the vein connection in the elbow |
on request |
|
| - no picture -
| CLA 23337 Plug ring red, Fastening for mounting the injection arm |
on request |
|
| - no picture -
| CLA 23340 case, made of plastic with handle |
on request |
|
| - no picture -
| CLA 23413 collecting container for anus praeter and PEG |
on request |
|
| - no picture -
| CLA 23421 Intestinal Tract |
on request |
|
| - no picture -
| CLA 23433/7 Bladder for the Female Abdominal Wall |
on request |
|
| - no picture -
| CLA 23433/8 Bladder for the Male Abdominal Wall |
on request |
|
| - no picture -
| CLA 23435 Disposable catheter 10 CH |
on request |
|
| - no picture -
| CLA 23441 Intestine tubes 18 CH |
on request |
|
| - no picture -
| CLA 23443 Curved Rectum |
on request |
|
| - no picture -
| CLA 23443/3 Plug-in for Rectum connection |
on request |
|
| - no picture -
| CLA 23444 Bladder Plug, 1 piece |
on request |
|
| - no picture -
| CLA 23500 Thigh, right without injection pad |
on request |
|
| - no picture -
| CLA 23503 Thigh, left without injection pad |
on request |
|
| - no picture -
| CLA 23511 Injection pad thigh, right |
on request |
|
| - no picture -
| CLA 23512 Injection pad thigh, left |
on request |
|
| - no picture -
| CLA 23520 Plug-in for knee, complete with push-button, 1 piece |
on request |
|
| - no picture -
| CLA 23522 Push-button for plug-in foot, knee and elbow |
on request |
|
| - no picture -
| CLA 23530 Lower leg, right |
on request |
|
| - no picture -
| CLA 23531 Foot, right |
on request |
|
| - no picture -
| CLA 23533 Lower leg, left |
on request |
|
| - no picture -
| CLA 23534 Foot, left |
on request |
|
| - no picture -
| CLA 23536 Plug-in for foot, complete with push button, 1 piece |
on request |
|
| - no picture -
| CLA 23700 Instruction key, German |
on request |
|
| - no picture -
| CLA 23702 Instruction key, English |
on request |
|
| - no picture -
| CLA 23704 Instruction key, French |
on request |
|
| - no picture -
| CLA 23706 Instruction key, Dutch |
on request |
|
| - no picture -
| CLA 23707 Instruction key, Spanish |
on request |
|
| - no picture -
| CLA 23800 Separating Spray, 200 ml |
on request |
|
| - no picture -
| CLA 23803 Blood-coloured liquid, bottle with 100 ml |
on request |
|
|
|